A Non-Destructive Approach to Characterize Nodularity in SG Iron Castings using Ultrasonic Testing

This study presents a comprehensive, non-destructive approach for evaluating nodularity in SG iron castings by integrating ultrasonic testing and microstructural analysis. The investigation focuses on three SG iron grades (400/12, 500/7, and 600/3) produced under varying casting conditions, including pouring temperatures (1380° C, 1400° C, 1420° C), carbon equivalent values (4.6, 4.3, 4.0), and section thicknesses (5 mm, 10 mm, 15 mm). Ultrasonic velocity measurements were carried out using the ultrasonic flaw detector with a 4 MHz transducer. Complementing this, microstructural examination of samples was conducted using an inverted trinocular microscope to validate nodularity levels. A linear regression model incorporating process parameters achieved a high predictive accuracy (R² = 0.8955). Microstructural analysis using an inverted trinocular microscope confirmed the reliability of ultrasonic results, showing consistent trends in nodularity evaluation. The study confirms that ultrasonic testing is a reliable, efficient, and cost-effective tool for assessing nodularity in SG iron castings. Major Findings: Nodularity showed strong correlation with ultrasonic velocity, and a regression model (R² = 0.8955) accurately predicted it using velocity, PT, CEV, and thickness. Higher PT (1420° C) and lower CEV (4.0) enhanced nodularity. Ultrasonic results closely matched microscopy, ensuring fast, cost-effective evaluation.

View article page

Download PDF