Failure Analysis of Wire Rope Used in Hoist System

During heavy lift operations in the hoist system, the steel wire rope in a 10-ton hoist crane system experienced catastrophic failure after 120 days of service, exhibiting severe structural damage. To determine the cause of failure, the samples from the damaged rope were investigated through visual inspection and stereomicroscopic and Scanning Electron Microscopy (SEM) analysis. Further, the nature of the damages was determined based on worksheet data collected to correlate operational conditions with potential failure mechanisms. The initial inspection results revealed that the localised failure zones in the upper-layer wires of the cable strands were not caused by fatigue. Stereomicroscopic and SEM analysis confirmed that localised plastic deformation and wear of individual wires led to the development of stress concentration, ultimately resulting in fatigue failure. All these occurrences were attributed to the operation of the crane hoist system and the conditions during installation. Major Findings: During heavy lift operations in the hoist system, the steel wire rope in a 10-ton hoist crane system experienced catastrophic failure after 120 days of service, exhibiting severe structural damage.

View article page

Download PDF