Charge-discharge behaviour of lead acid battery and lead carbon hybrid ultracapacitors as anintegrated system for solar power applications

The paper discussess ome of the practical issues on direct parallel integration of lead acid battery and lead carbon hybrid ultra-capacitor to form an integrated energy storage system for solar power applications. The integrated energy storage system is subjected to various C rates to analyze the behavior of charging and discharging of HUC. The percentage contribution of HUC, in charging and discharging of the integrated energy storage system would be a useful information, while coupling battery and HUC in solar power applications. In view of this, experimental studies have been carried out at different C rates and results are presented.