Evaluation of LSZH Materials of Network Data Cables

In general network data transmission cables have Low Smoke Zero Halogen (LSZH) or Halogen Free Fire Retardant (HFFR) materials as outer protection covering or sheathing. During the fire and smoke property assessment such type of network cables adequately meet the requirement of the standard with respect to fire retardancy and smoke release. In one of the cables, the smoke properties are found in order, however, it did not meet the flame retardancy properties such as Oxygen Index and Temperature Index. To figure out the reason two different samples, i.e., passed and failed are subjected to various material characterization assessments such as Thermo Gravimetric Analysis (TGA) and Fourier Transform Infrared Spectroscopy (FTIR) are carried out. The physical properties such as Tensile Strength, % Elongation and Hot deformation characteristics are also carried out for both samples. From the results, it has been observed that the percentage weight of the inorganic material present in the LSZH materials, non-uniform dispersion of these filler materials and the type of filler materials play a vital role in influencing the fire and smoke properties of the LSZH sheathing materials. The optimum selection of organic filler material and the correct method of mixing is required to achieve the desired properties.