Coal Quality Change Due to Handling and Stockpiling in an Indian Power Plant: A Case Study (Part-2-The Results and Inference)
In the open transportation of coal by wagons or trucks, external moisture due to rain coupled with oxidation, the loss of quality in terms of the heat value of coal is nearly unavoidable. And when in the stock pile, there is a likelihood of loss up to 5% of the gross calorific value over a period of 3-4 months in open stocks/stacks. This study however, reports a technological challenge to ascertain the coal in the standard practice of coal handling from train to stock and then from the stock to the firing. The technological and practice level challenge is that as the coal gets crushed and milled, the heavier impurities during vibration and movement, an even in static condition, tend to settle at the bottom. And so measuring coal quality by sampling at the top of the belt or by cut sampling during flow provides higher than actual gross thermal value obtained for the whole mass. This aspect needs to be studied in detailed and correctional factor(s) may be adopted to find the actual thermal value of coal, finally being obtained at the firing circuit and the boiler.