A New Electrochemical Carbon Meter for Monitoring Carbon Activity in Liquid Sodium
Liquidsodiumisusedascoolantinfastbreederreactors.Carbonisanimportantconstituentofsteels. The carbon atoms can readily diffuse across sodium-steel interfaces in sodium loops of fast breeder reactors. The carbon activity difference between the structural steel and sodium can lead to carburisation or decarburisation of structural steels. In order to monitor the carbon activity in liquid sodium, a compact electrochemical carbon meter (ECCM) has been developed. The performance of the meter was tested in static sodium at 848 to 998 K. The chemical activity of carbon determined was compared with the results obtained by equilibration studies.