Pulsed Electrodeposition Of Palladium In 1-butyl-3-Methylimidazolium Chloride Ionic Liquid Medium For The Application In Proton Exchange Membrane Based H<sub>2</sub> Sensors
Palladium is a well-known electrocatalyst for amperometric sensing of hydrogen. Pd has higher solubility and sticking coefficient towards H2 which facilitates better sensor performance compared to other metals. Many methods are available for the preparation of electrocatalyst such as vapour depositions, chemical reduction etc. Electrodeposition method considered to be advantageous compared to conventional methods owing to the ability to control particle size, easy preparation and devoid of wastage of catalyst. H2 embrittlement is significant in electrodepositing Pd using aqueous electrolyte. Hence, room temperature ionic lquid (RTIL) has widely been used to avoid H2 evolution during electrodeposition. In the present work Pd is electrodeposited on gas diffusion electrode (GDE) using C4mimCl as electrolyte. Unlike electrodeposition (ED) pulsed electrodeposition (PED) reduces diffusion layer thickness by giving on and off time pulses. This in turn reflects in the morphology of the deposit as increased effective surface area of Pd in PED. Cyclic voltammetry was carried out to study the reduction potential of Pd in C4mimCl electrolyte. Pd is electrodeposited on GDE by applying constant potential as well as pulse potential. XRD confirms the deposition of Pd and crystallite size is calculated using scherrer’s formula. Pulsed electrodeposition gives higher surface area as seen from FESEM images of ED and PED Pd/GDE. Electrochemical active area of PED Pd/GDE is found to be higher than the ED. High electrochemical active area gives better sensitivity and stability in amperometric based H2 sensors.