Performance Analysis of Blast-Induced Ground Vibration Measuring Sensors at Low-Frequency Excitation
Measurement of ground vibration due to blasting is a mandatory practice in Indian surface mines. Three dominant sensors, namely Piezoelectric Accelerometers (PA), Micro-Electro-Mechanical Systems (MEMS) accelerometers and electro-magnetic Geophone, are, in general, used to measure the oscillation of the ground and thus record information related to the parameters associated with ground vibration. A controlled laboratory-based vibrational analysis is carried out with the help of a shaker table using a MEMS-based accelerometer and an electromagnetic-based Geophone at excitation signals of 3 Hz, 10 Hz, and 30 Hz frequencies. The excitation velocity for each frequency signal varies between 3 mm/s to 60 mm/s. The sensor’s response, as output voltage, is found to vary from 10 mV to 400 mV for MEMS accelerometers and from 10 mV to 1600 mV for electromagnetic geophones. Deviation in the sensors’ response in these frequencies is studied along with statistical analysis. The results revealed that the sensors responded properly above a certain excitation signal frequency. At lower frequencies, the response of the sensors is found to be inconsistent and affected by noise. For all the sensors, improved responses are observed with increasing frequency and peak amplitudes. Irrespective of various input amplitude velocities, the sensitivity remained constant for each fixed frequency; however, it increased proportionately with the rise in frequencies. In regression analysis, the geophone was proved to be more consistent than the MEMS accelerometer.