Evaluating Thermal Retention Performance of a Solar Water Heater: Cooling Time Constant Assessment
The performance of solar water heater system is assessed by system efficiency and cooling time constant. Computation of these parameters for thermosiphon type solar water heater is given in IS 16368 (2015). In this article, the thermal retention performance is assessed for 100-litre flat plate solar water heater using cooling time constant. The tests conducted for 14 nights with different initial temperatures of water. It was observed that higher the initial water temperature, lower will be the cooling time constant.