Comparison of Volumetric Analysis of Lateral Compaction & Three Different Vertically Compacted Thermoplasticized Obturation Techniques Using Spiral CT - An In Vitro Study

Jump To References Section

Authors

  • Post Graduate Student, Department of Conservative Dentistry & Endodontics, S.D.K.S Dental College & Hospital, Nagpur ,IN
  • Professor, Department of Conservative Dentistry & Endodontics, S.D.K.S Dental College & Hospital, Nagpur ,IN
  • Professor and Head, Department of Conservative Dentistry & Endodontics, S.D.K.S Dental College & Hospital, Nagpur ,IN

Keywords:

Lateral Condensation, Thermoplasticized Gutta Percha, Spiral Computed Tomography
Conservative Dentistry & Endodontics

Abstract

The objective of endodontic obturation is to provide a complete seal along the length of root canal system. This study was conducted to compare volumetrically, the laterally compressed gutta percha with three different vertically compacted thermoplasticized obturating systems using spiral CT, an in vitro study. Materials and methods included preparation of access cavities in 20 single rooted mandibular first premolars, followed by cleaning and shaping. Obturation was done with different thermoplasticized obturation systems: Group A - cold lateral; Group B - Calamus dual; Group C - E & Q Plus; Group D - Obtura II. Volume analysis was done using spiral computed tomography (CT). The percentage difference was calculated & statistically analyzed using one-way ANOVA and multiple comparisons between groups using Tukey's HSD test. The results of study has shown the statistical significance between all the groups with the p-value <0.0001. Multiple comparisons between different groups show statistical significance in all groups except Group C and Group D. With this significance in results, it can be concluded that Calamus dual showed the highest volume of obturation, followed by Obtura II and E & Q Plus. The least volume of obturation was observed in cold lateral condensation technique.

Published

2018-11-06

How to Cite

Tibdewal, G. S., Gade, V. J., & Asrani, H. (2018). Comparison of Volumetric Analysis of Lateral Compaction & Three Different Vertically Compacted Thermoplasticized Obturation Techniques Using Spiral CT - An In Vitro Study. Journal of Pierre Fauchard Academy (India Section), 27(2), 60–66. Retrieved from https://informaticsjournals.com/index.php/jpfa/article/view/22649

Issue

Section

Original Articles

 

References

Johnson WT, Kulild J. Obturation of the root canal system. In: Hargreaves K, Cohen S, eds. Pathways of the Pulp. 10th ed. Elsevier Mosby Pub; 2011.

Dulac K, Nielsen C, Tomazic T, Ferrillo P, Hatton J. Comparison of the lateral canals by six techniques. J Endod. 1999;25:376.

Peng Li, Ling Ye, Tan H, Xuedong Z. Outcome of root canal obturation by warm gutta-percha versus cold lateral condensation: a meta-analysis. J Endod. 2007;33(2):106-109.

Karabucak B, Kim A, Chen V, Iqbal M. The comparison of gutta-percha and resilon penetration into lateral canals with different thermoplastic delivery system. J Endod. 2008;34(7):847-849.

Budd C, Weller R, Kulid J. A comparison of thermoplasticized injectable gutta-percha obturation techniques. J Endod. 1991;17:260-264.

Wu M, Kastakova A, Wesselink PR. Quality of cold and warm gutta-percha fillings in oval canals in mandibular premolars. Int Endod J. 2001;34:485.

Nandini S, Velmurugan N, Kandawamy D. Removal efficiency of calcium hydroxide intracanal medicament with two calcium chelators: volumetric analysis using spiral CT, an in vitro study. J Endod. 2006;32:1097-1101.

Kandaswamy D, Venketeshbabu N, Gopikrishna R, Hannah R, Arathi G, Roohi R. Compaction of laterally condensed, vertically compacted thermoplastized, cold free flow GP obturations e a volumetric analysis using spiral CT. J Conserv Dent. 2009;2(4):145-149.

Margelos J, Eliades G, Verdalis C, Palaghias G. Interaction of calcium hydroxide with zinc oxide eugenol type sealers: a potential clinical problem. J Endod. 1997;23:43-48.

Lambrianidis T, Margelos J, Beltes P. Removal efficiency of calcium hydroxide dressing from the root canal. J Endod. 1999;25:85-88.

Capurro MA, Goldberg F, Balbachan L, Macchi RL. Evaluation of the dimensional stability of different thermoplasticized gutta-percha fillings using simulated glass root canals. Endod Dent Traumatol. 1993;9:160-164.

Goldberg F, Artaza LP, De S. Influence of calcium hydroxide dressing on the obturation of simulated lateral canals. J Endod. 2002;28:99-101.

Ingle JI, Simon JH, Machtou P, Bogaerts P. Endodontic cavity preparation. In: Ingle. J, Backland. L, eds. Endodontics. 5th ed. BC Decker Inc; 2002:328-336.

Najla Al-Dewani S, Hayes J, Michal P, Dummer H. Comparison of laterally condensed and low temperature thermoplasticized gutta-percha root fillings. J Endod. 2000;26(12):733-738.

Tani-Ishii N, Teranak N. Clinical and radiographic evaluation of root canal obturation with Obtura II. J Endod. 2003;29(11):739-742.

Anari B, Umar F, Raza Khan F. A clinical trial of cold lateral compaction with obtura II technique in root canal obturation. J Conserv Dent. 2012;15(2):156-160.

Tanomaru M, Santa Jr A, Basso R, Maria J, Tanomaru G. Effectiveness of gutta-percha and resilon in filling lateral canals using the Obtura II system. Braz Oral Res. 2011;25(3):205-209.

Yelton C, Walke MP, Lee C, Dryde J, Kulid J. Assessment of a thermoplasticized gutta-percha delivery system to effectively obturate canals with varying preparation dimensions. J Endod. 2007;33:156-159.

Goldberg F, Artaza L, De Silvio A. Effectiveness of different obturation techniques in the filling of stimulated lateral canals. J Endod. 2001;2:362-364.

Collins J, Mary P, Kulid J, Lee C. A comparison of three guttapercha obturation technique to replicate canal irregularities. J Endod. 2006;32:762-765.

Lea CS, Apicella MJ, Mines P, Yancich P, Parker MH. Comparison of the obturation density of cold lateral compaction versus warm vertical compaction using the continuous wave of obturation technique. J Endod. 2005;31:37-39.

Calhoun PS, Kuszyk BS, Heath DG, Carley JC, Fishman EK. Three-dimensional volume rendering of spiral CT data: theory and method. Radiographics. 1999;19:745-764.

Venturi M, Di Lenarda R, Breschi L. An ex vivo comparison of three different gutta-percha cones when compacted at different temperatures: rheological considerations in relation to the filling of lateral canals. Int Endod J. 2006;39:648-656.

Gurgel-Filho ED, Feitosa JP, Gomes BP, Ferraz CC, SouzaFilho FJ, Teixeira FB. Assessment of different gutta-percha brands during the filling of simulated lateral canals. Int Endod J. 2006;39:113-118.

Lea CS, Apicella MJ, Mines P, Yancich P, Parker MH.Compaction of the obturation density of cold lateral compaction versus warm vertical compaction using the continuous wave of condensation Technique. J Endod. 2005;31:37-39.

Marlin J, Krakow AA, Desilets RP, Gron P. Clinical use of injection molded thermoplasticized gutta-percha for obturation of the root canal system: a preliminary report. J Endod. 1981;7:277-281.

Peters DD. Two-year in vitro solubility evaluation of four gutta-percha sealer obturation techniques. J Endod. 1986;12:139-145.

Weller RN, Kimbrough WF, Anderson RW. A comparison of thermoplastic techniques: adaptation to the canal walls. J Endod. 1997;23:703-706.

Holcomb J, Pitts D, Nicholls J. Further investigation of spreader loads required to cause vertical root fracture during lateral condensation. J Endod. 1987;13:277-284.

Lertchirakarn V, Palamara JEA, Messer HH. Load and strain during lateral condensation and vertical root fracture. J Endod. 1999;25:99-104.

Buchanan LS. The continuous wave of condensation technique: a convergence of conceptual and procedural advances in obturation. Dent Today. 1994;13, 80, 82, 84-85.

Sweatman T, Baumgartner J, Sakguichi R. Radicular temperatures associated with thermoplasticized guttapercha. J Endod. 2001;27:512-515.

Floren JW, Weller RN, Pashley DH, Kimbrough WF. Changes in root surface temperatures with in vitro use of the system B heatsource. J Endod. 1999;25:593-595.

Bowman C, Baumgartner J. Gutta-percha obturation of lateral grooves and depressions. J Endod. 2002;28:220-223.

Johnson BT, Bond MS. Leakage associated with single or multiple increment backfill with the Obtura II gutta-percha system. J Endod. 1999;25:613-614.

Jacobson H, Baumgartner J. Gutta-percha obturation of lateral grooves and depressions. J Endod. 2002;28:269-271.

DuLac KA, Nielsen CJ, Tomazic TJ, Ferrillo PJ, Hatton JF. Comparison of the obturation of lateral canals by six techniquesJr, ed. Endod Prac. 1998;1:7-10, 13-6.